- Quality Control
-
-
Wicker Quality
All of OUTDOOR MASTER quotations are just based on the normal China wicker, which still could guarantee 2 years for outdoor usage. As a professional manufacturer of high quality wicker furniture, we recommend REHAU(For more information,please click) Synthetic fiber to the top quality level market, which could guarantee at least 5 years. Through the price is high, but it is a reasonable price if you take the quality into consideration. Our skilled workers have enough experience in working REHAU Synthetic fiber. Please check the following technical data sheet of REHAU Products.
REHAU Synthetic Fiber
RAUCORD Properties: -UV Resistant -Environmentally friendly -Weatherproof -High Tensile Strength -Chemical Resistant -Colourfast |
|
REHAU Quality StandardMechanical Properties
Test Item |
Value |
Unit |
Test Method |
Density |
952 |
kg/m^3 |
ISO 1183 Method D |
Flexural Modulus |
1500 |
Mpa |
ISO 178 |
Charpy Impact Strength |
10 |
KJ/m^2 |
ISO 179 Type 1 Notch A |
Hardness (Shore D) |
65 |
|
ISO 868 Type D |
Melting Point |
131 |
C |
ISO 3146 Method C |
Vicat Softening Point |
126 |
C |
ISO 306 |
Brittleness Temperature |
< -70 |
C |
ISO 974: 2000 |
Thermal Conductivity |
0.48 |
W/M C |
ASTM C177 |
Specific Heat |
2300 |
J/kg C |
ASTM C351 |
Coefficient of Linear Expansion |
63/10^6 |
1/C |
ASTM D696-91 | Physical Properties
Properties |
Value |
Unit |
Test Reference |
Tensile Strength at Yield |
>20 |
Mpa |
ISO 527 |
Elongation at Break |
>600 |
% |
ISO 178 |
Weather Resistance: |
|
Artificial Weathering and Ageing Xenon Arc Radiation |
>3500. (Pulut, Shimmer, Pearl & Linea Range) >5000 (Abaca, Classic, Loom & Natural Range) |
Hours |
DIN 53387 |
Grey Scale Classification after test |
4-5 |
|
the grey scale classification was determined under the D65 standard light, class 5 is the best and class 1 is the worst. | Cushion
|
|
|